Search Results (2336 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-37997 1 Siemens 2 Jt Open, Plm Xml Sdk 2026-04-15 7.8 High
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-33498 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 5.3 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.
CVE-2024-52334 1 Siemens 1 Syngo Plaza Vb30e 2026-04-15 5.3 Medium
A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF07). The affected application does not encrypt the passwords properly. This could allow an attacker to recover the original passwords and might gain unauthorized access.
CVE-2024-38278 1 Siemens 32 Ruggedcom Ros Rmc8388, Ruggedcom Ros Rmc8388nc, Ruggedcom Ros Rs416ncv2 and 29 more 2026-04-15 6.6 Medium
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.9.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.9.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900GNC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900NC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100NC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2288 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2288NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300P V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300PNC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2488 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2488NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG907R (All versions < V5.9.0), RUGGEDCOM RSG908C (All versions < V5.9.0), RUGGEDCOM RSG909R (All versions < V5.9.0), RUGGEDCOM RSG910C (All versions < V5.9.0), RUGGEDCOM RSG920P V5.X (All versions < V5.9.0), RUGGEDCOM RSG920PNC V5.X (All versions < V5.9.0), RUGGEDCOM RSL910 (All versions < V5.9.0), RUGGEDCOM RSL910NC (All versions < V5.9.0), RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0), RUGGEDCOM RST916C (All versions < V5.9.0), RUGGEDCOM RST916P (All versions < V5.9.0). The affected products with IP forwarding enabled wrongly make available certain remote services in non-managed VLANs, even if these services are not intentionally activated. An attacker could leverage this vulnerability to create a remote shell to the affected system.
CVE-2025-40743 1 Siemens 4 Sinumerik 828d, Sinumerik 840d Sl, Sinumerik Mc and 1 more 2026-04-15 8.3 High
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2024-39675 1 Siemens 24 Ruggedcom Ros Rmc30, Ruggedcom Ros Rmc30nc, Ruggedcom Ros Rp110 and 21 more 2026-04-15 8.8 High
A vulnerability has been identified in RUGGEDCOM RMC30 (All versions < V4.3.10), RUGGEDCOM RMC30NC (All versions < V4.3.10), RUGGEDCOM RP110 (All versions < V4.3.10), RUGGEDCOM RP110NC (All versions < V4.3.10), RUGGEDCOM RS400 (All versions < V4.3.10), RUGGEDCOM RS400NC (All versions < V4.3.10), RUGGEDCOM RS401 (All versions < V4.3.10), RUGGEDCOM RS401NC (All versions < V4.3.10), RUGGEDCOM RS416 (All versions < V4.3.10), RUGGEDCOM RS416NC (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416P (All versions < V4.3.10), RUGGEDCOM RS416PNC (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS910 (All versions < V4.3.10), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910LNC (All versions), RUGGEDCOM RS910NC (All versions < V4.3.10), RUGGEDCOM RS910W (All versions < V4.3.10), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920LNC (All versions), RUGGEDCOM RS920W (All versions). In some configurations the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability.
CVE-2024-52335 1 Siemens 1 Syngo Plaza Vb30e 2026-04-15 9.8 Critical
A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database.
CVE-2025-40815 1 Siemens 2 Logo!, Siplus Logo! 2026-04-15 7.2 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
CVE-2024-35292 1 Siemens 10 Simatic S7-200 Smart Cpu Cr40, Simatic S7-200 Smart Cpu Cr60, Simatic S7-200 Smart Cpu Sr20 and 7 more 2026-04-15 8.2 High
A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices are using a predictable IP ID sequence number. This leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition.
CVE-2024-41171 1 Siemens 3 Sinumerik 828d Firmware, Sinumerik 840d Sl Firmware, Sinumerik One Firmware 2026-04-15 8.8 High
A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions < V6.24). Affected devices do not properly enforce access restrictions to scripts that are regularly executed by the system with elevated privileges. This could allow an authenticated local attacker to escalate their privileges in the underlying system.
CVE-2024-32639 1 Siemens 1 Tecnomatix Plant Simulation 2026-04-15 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)
CVE-2025-40570 1 Siemens 1 Siprotec 5 2026-04-15 2.4 Low
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability.
CVE-2025-40816 1 Siemens 2 Logo!, Siplus Logo! 2026-04-15 7.6 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
CVE-2024-30321 1 Siemens 3 Simatic Pcs 7, Simatic Wincc, Simatic Wincc Runtime Professional 2026-04-15 5.9 Medium
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information. This could allow an unauthenticated remote attacker to retrieve information such as users and passwords.
CVE-2025-40827 1 Siemens 2 Software Center, Solid Edge Se2025 2026-04-15 7.8 High
A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system.
CVE-2025-40744 1 Siemens 1 Solid Edge Se2025 2026-04-15 7.5 High
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 11). Affected applications do not properly validate client certificates to connect to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
CVE-2025-40763 1 Siemens 1 Altair Grid Engine 2026-04-15 7.8 High
A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution. This could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path.
CVE-2025-40587 1 Siemens 1 Polarion 2026-04-15 7.6 High
A vulnerability has been identified in Polarion V2404 (All versions < V2404.5), Polarion V2410 (All versions < V2410.2). The affected application allows arbitrary JavaScript code be included in document titles. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by creating specially crafted document titles that are later viewed by other users of the application.
CVE-2024-33499 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group.