| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The zmq3 input and output modules in rsyslog before 8.28.0 interpreted description fields as format strings, possibly allowing a format string attack with unspecified impact. |
| An Externally Controlled Format String issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. String format specifiers based on user provided input are not properly validated, which could allow an attacker to execute arbitrary code. |
| In Wireshark 2.4.0 to 2.4.1, 2.2.0 to 2.2.9, and 2.0.0 to 2.0.15, the DMP dissector could crash. This was addressed in epan/dissectors/packet-dmp.c by validating a string length. |
| An issue was discovered in certain Apple products. macOS before 10.12.4 is affected. The issue involves the "Printing" component. A format-string vulnerability allows remote attackers to execute arbitrary code via a crafted ipp: or ipps: URL. |
| The Bluetooth stack on the BMW 330i 2011 allows a remote crash of the CD/Multimedia software via %x or %c format string specifiers in a device name. |
| A format string injection vulnerability exists in the ghome_process_control_packet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted XCMD can lead to memory corruption, information disclosure and denial of service. An attacker can send a malicious XML payload to trigger this vulnerability. |
| A format string injection vulnerability exists in the XCMD getVarHA functionality of abode systems, inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted XCMD can lead to memory corruption, information disclosure, and denial of service. An attacker can send a malicious XML payload to trigger this vulnerability. |
| Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `ssid` and `ssid_hex` configuration parameters, as used within the `testWifiAP` XCMD handler |
| Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `wpapsk` configuration parameter, as used within the `testWifiAP` XCMD handler |
| Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` and `key` configuration parameters, as used within the `testWifiAP` XCMD handler |
| Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` configuration parameter, as used within the `testWifiAP` XCMD handler |
| Four format string injection vulnerabilities exist in the UPnP logging functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted UPnP negotiation can lead to memory corruption, information disclosure, and denial of service. An attacker can host a malicious UPnP service to trigger these vulnerabilities.This vulnerability arises from format string injection via `ST` and `Location` HTTP response headers, as used within the `DoEnumUPnPService` action handler. |
| Four format string injection vulnerabilities exist in the UPnP logging functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted UPnP negotiation can lead to memory corruption, information disclosure, and denial of service. An attacker can host a malicious UPnP service to trigger these vulnerabilities.This vulnerability arises from format string injection via `controlURL` XML tag, as used within the `DoUpdateUPnPbyService` action handler. |
| Four format string injection vulnerabilities exist in the UPnP logging functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted UPnP negotiation can lead to memory corruption, information disclosure, and denial of service. An attacker can host a malicious UPnP service to trigger these vulnerabilities.This vulnerability arises from format string injection via `NewInternalClient` XML tag, as used within the `DoUpdateUPnPbyService` action handler. |
| Four format string injection vulnerabilities exist in the UPnP logging functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted UPnP negotiation can lead to memory corruption, information disclosure, and denial of service. An attacker can host a malicious UPnP service to trigger these vulnerabilities.This vulnerability arises from format string injection via `errorCode` and `errorDescription` XML tags, as used within the `DoUpdateUPnPbyService` action handler. |
| Four format string injection vulnerabilities exist in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted HTTP request can lead to memory corruption, information disclosure and denial of service. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability arises from format string injection via the `ssid_hex` HTTP parameter, as used within the `/action/wirelessConnect` handler. |
| Four format string injection vulnerabilities exist in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted HTTP request can lead to memory corruption, information disclosure and denial of service. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability arises from format string injection via the `wpapsk_hex` HTTP parameter, as used within the `/action/wirelessConnect` handler. |
| Four format string injection vulnerabilities exist in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted HTTP request can lead to memory corruption, information disclosure and denial of service. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` and `key` HTTP parameters, as used within the `/action/wirelessConnect` handler. |
| Four format string injection vulnerabilities exist in the web interface /action/wirelessConnect functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted HTTP request can lead to memory corruption, information disclosure and denial of service. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` HTTP parameter, as used within the `/action/wirelessConnect` handler. |
| A vulnerability was found in multimon-ng. It has been rated as critical. This issue affects the function add_ch of the file demod_flex.c. The manipulation of the argument ch leads to format string. Upgrading to version 1.2.0 is able to address this issue. The name of the patch is e5a51c508ef952e81a6da25b43034dd1ed023c07. It is recommended to upgrade the affected component. The identifier VDB-216269 was assigned to this vulnerability. |