| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The web server of the device performs exchanges of sensitive information in clear text through an insecure protocol. |
| The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database contains the whole configuration. This includes encrypted MIFARE keys, card data, user PINs and much more. The PINs are even stored unencrypted. Combined with the fact that an attacker can easily get access to the backup functionality by abusing the session management issue (CVE-2025-59101), or by exploiting the weak default password (CVE-2025-59108), or by simply setting a new password without prior authentication via the SOAP API (CVE-2025-59097), it is easily possible to access the sensitive data on the device. |
| Obsidian GitHub Copilot Plugin versions prior to 1.1.7 store Github API token in cleartext form. As a result, an attacker may perform unauthorized operations on the linked Github account. |
| RAD SecFlow-2 devices with Hardware 0202, Firmware 4.1.01.63, and U-Boot 2010.12 allow URIs beginning with /.. for Directory Traversal, as demonstrated by reading /etc/shadow. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| DuraComm SPM-500 DP-10iN-100-MU
transmits sensitive data without encryption over a channel that could be intercepted by attackers. |
| Cleartext transmission of sensitive information issue exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a man-in-the-middle attack may allow a remote unauthenticated attacker to eavesdrop the communication and obtain the authentication information. |
| Arctera/Veritas Data Insight before 7.1.2 can send cleartext credentials when configured to use HTTP Basic Authentication to a Dell Isilon OneFS server. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Hub 0382, YoLink Mobile Application 1.40.41, and YoLink MQTT Broker. NOTE: The vendor states that the vulnerability described (related to insecure transmission) only impacts the legacy mobile application logic, not the Hub hardware or firmware. The Hub functions solely as a pass-through (transparent gateway) for LoRa wireless data and does not inspect or process the application layer data. |
| Kaleris NAVIS N4 ULC (Ultra Light Client) communicates insecurely using zlib-compressed data over HTTP. An attacker capable of observing network traffic between Ultra Light Clients and N4 servers can extract sensitive information, including plaintext credentials. |
| Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site.
This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior. |
| Cleartext storage of sensitive information in the Zoom Jenkins Marketplace plugin before version 1.4 may allow an authenticated user to conduct a disclosure of information via network access. |
| Ecovacs Deebot T10 1.7.2 transmits Wi-Fi credentials in cleartext during the pairing process. |
| An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure. |
| This vulnerability exists in the Meon KYC solutions due to transmission of sensitive data in plain text within the response payloads of certain API endpoints. An authenticated remote attacker could exploit this vulnerability by intercepting API response that contains unencrypted sensitive information belonging to other users.
Successful exploitation of this vulnerability could allow remote attacker to impersonate the target user and gain unauthorized access to the user account. |
| SAP GUI for Windows may allow a highly privileged user on the affected client PC to locally access sensitive information stored in process memory during runtime.This vulnerability has a high impact on confidentiality, with no impact on integrity and availability. |
| Toshiba printers will display the password of the admin user in clear-text and additional passwords when sending 2 specific HTTP requests to the internal API. An attacker stealing the cookie of an admin or abusing a XSS vulnerability can recover this password in clear-text and compromise the printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| Vulnerable data in transit in GE HealthCare EchoPAC products |