| A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database. |
| Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| An issue was discovered on the D-Link DWR-932B router. There is a hardcoded WPS PIN of 28296607. |
| An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234. |
| The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials. |
| A vulnerability in Cisco Umbrella Insights Virtual Appliances 2.1.0 and earlier could allow an authenticated, local attacker to log in to an affected virtual appliance with root privileges. The vulnerability is due to the presence of default, static user credentials for an affected virtual appliance. An attacker could exploit this vulnerability by using the hypervisor console to connect locally to an affected system and then using the static credentials to log in to an affected virtual appliance. A successful exploit could allow the attacker to log in to the affected appliance with root privileges. Cisco Bug IDs: CSCvg31220. |
| MEDHOST Document Management System contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. PostgreSQL is used as the Document Management System database. The account name is dms. The password is hard-coded throughout the application, and is the same across all installations. Customers do not have the option to change passwords. The dms account for PostgreSQL has access to the database schema for Document Management System. |
| MEDHOST Connex contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. Connex utilizes an IBM i DB2 user account for database access. The account name is HMSCXPDN. Its password is hard-coded in multiple places in the application. Customers do not have the option to change this password. The account has elevated DB2 roles, and can access all objects or database tables on the customer DB2 database. This account can access data through ODBC, FTP, and TELNET. Customers without Connex installed are still vulnerable because the MEDHOST setup program creates this account. |
| EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system. |
| D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access. |
| CloudForms Management Engine before 5.8 includes a default SSL/TLS certificate. |
| On the TP-Link TL-SG108E 1.0, there is a hard-coded ciphering key (a long string beginning with Ei2HNryt). This affects the 1.1.2 Build 20141017 Rel.50749 firmware. |
| The Epson "EasyMP" software is designed to remotely stream a users computer to supporting projectors.These devices are authenticated using a unique 4-digit code, displayed on-screen - ensuring only those who can view it are streaming.In addition to the password, each projector has a hardcoded "backdoor" code (2270), which authenticates to all devices. |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). |
| An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass |
| Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET. |
| On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root"). The attacker can make a user that is connected to the repeater click on a malicious link that will log into the telnet and will infect the device with malicious code. |
| On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not). |