Search Results (821 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-4832 1 Schneider-electric 25 Easergy P14x, Easergy P24x, Easergy P341 and 22 more 2026-04-17 N/A
CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port.
CVE-2026-1286 1 Schneider-electric 2 Ecostruxure Foxboro Dcs Control Software, Foxboro Dcs 2026-04-17 6.5 Medium
CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file.
CVE-2026-2273 1 Schneider-electric 1 Ecostruxure Automation Expert 2026-04-17 8.2 High
CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.
CVE-2025-9996 1 Schneider-electric 1 Blmon 2026-04-15 N/A
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session.
CVE-2025-9997 1 Schneider-electric 1 Blmon 2026-04-15 N/A
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
CVE-2025-54923 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 N/A
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization.
CVE-2025-8448 1 Schneider-electric 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation 2026-04-15 N/A
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products.
CVE-2025-8453 1 Schneider-electric 2 Saitel Dp, Saitel Dr 2026-04-15 6.7 Medium
CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and arbitrary code execution when a privileged engineer user with console access modifies a configuration file used by a root-level daemon to execute custom scripts.
CVE-2025-8449 1 Schneider-electric 3 Ecostruxure Building Operation Enterprise Server, Ecostruxure Enterprise Server, Ecostruxure Workstation 2026-04-15 N/A
CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network.
CVE-2025-7746 1 Schneider-electric 1 Altivar 2026-04-15 N/A
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.
CVE-2025-6625 1 Schneider-electric 12 Bmxngd0100, Bmxngd0100 Firmware, Bmxnoc0401 and 9 more 2026-04-15 7.5 High
CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device.
CVE-2025-54924 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 7.5 High
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.
CVE-2025-54925 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 7.5 High
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.
CVE-2025-54926 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 7.2 High
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.
CVE-2025-54927 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 4.9 Medium
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system.
CVE-2025-13905 1 Schneider-electric 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform 2026-04-15 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
CVE-2025-11565 1 Schneider-electric 1 Powerchute Serial Shutdown 2026-04-15 N/A
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.
CVE-2025-11566 1 Schneider-electric 1 Powerchute Serial Shutdown 2026-04-15 N/A
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.
CVE-2025-11567 1 Schneider-electric 1 Powerchute Serial Shutdown 2026-04-15 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.
CVE-2024-8518 1 Schneider-electric 1 Zelio Soft 2 2026-04-15 3.3 Low
CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft 2 application when a specially crafted project file is loaded by an application user.