Search Results (750 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-55539 2026-04-15 N/A
Weak algorithm used to sign RPM package. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux) before build 39185, Acronis Cyber Protect 16 (Linux) before build 39938.
CVE-2025-45767 2026-04-15 7 High
jose v6.0.10 was discovered to contain weak encryption. NOTE: this is disputed by a third party because the claim of "do not meet recommended security standards" does not reflect guidance in a final publication.
CVE-2025-45764 2026-04-15 3.2 Low
jsrsasign v11.1.0 was discovered to contain weak encryption. NOTE: this issue has been disputed by a third party who believes that CVE IDs can be assigned for key lengths in specific applications that use a library, and should not be assigned to the default key lengths in a library. This dispute is subject to review under CNA rules 4.1.4, 4.1.14, and other rules; the dispute tagging is not meant to recommend an outcome for this CVE Record.
CVE-2025-41223 2026-04-15 4.8 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected devices support the TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256 cipher suite, which uses CBC (Cipher Block Chaining) mode that is known to be vulnerable to timing attacks. This could allow an attacker to compromise the integrity and confidentiality of encrypted communications.
CVE-2025-27508 2026-04-15 7.5 High
Emissary is a P2P based data-driven workflow engine. The ChecksumCalculator class within allows for hashing and checksum generation, but it includes or defaults to algorithms that are no longer recommended for secure cryptographic use cases (e.g., SHA-1, CRC32, and SSDEEP). These algorithms, while possibly valid for certain non-security-critical tasks, can expose users to security risks if used in scenarios where strong cryptographic guarantees are required. This issue is fixed in 8.24.0.
CVE-2025-26486 2026-04-15 6 Medium
Broken or Risky Cryptographic Algorithm, Use of Password Hash With Insufficient Computational Effort, Use of Weak Hash, Use of a One-Way Hash with a Predictable Salt vulnerabilities in Beta80 "Life 1st Identity Manager" enable an attacker with access to password hashes to bruteforce user passwords or find a collision to ultimately while attempting to gain access to a target application that uses "Life 1st Identity Manager" as a service for authentication. This issue affects Life 1st: 1.5.2.14234.
CVE-2023-41927 2026-04-15 5.3 Medium
The server supports at least one cipher suite which is on the NCSC-NL list of cipher suites to be phased out, increasing the risk of cryptographic weaknesses.
CVE-2025-7214 1 Fnkvision 1 Fnk-gu2 2026-04-15 1.6 Low
A vulnerability classified as problematic was found in FNKvision FNK-GU2 up to 40.1.7. Affected by this vulnerability is an unknown functionality of the file /etc/shadow of the component MD5. The manipulation leads to risky cryptographic algorithm. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2023-52236 2026-04-15 7 High
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected products support insecure cryptographic algorithms. An attacker could leverage these legacy algorithms to achieve a man-in-the-middle attack or impersonate communicating parties.
CVE-2023-41928 2026-04-15 5.3 Medium
The device is observed to accept deprecated TLS protocols, increasing the risk of cryptographic weaknesses.
CVE-2025-9383 1 Fnkvision 1 Y215 Cctv Camera 2026-04-15 2.5 Low
A security vulnerability has been detected in FNKvision Y215 CCTV Camera 10.194.120.40. This issue affects the function crypt of the file /etc/passwd. The manipulation leads to use of weak hash. The attack can only be performed from a local environment. The complexity of an attack is rather high. The exploitability is assessed as difficult. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-9317 1 Aveva 1 Edge 2026-04-15 8.4 High
The vulnerability, if exploited, could allow a miscreant with read access to Edge Project files or Edge Offline Cache files to reverse engineer Edge users' app-native or Active Directory passwords through computational brute-forcing of weak hashes.
CVE-2025-7383 2026-04-15 N/A
Padding oracle attack vulnerability in Oberon microsystem AG’s Oberon PSA Crypto library in all versions since 1.0.0 and prior to 1.5.1 allows an attacker to recover plaintexts via timing measurements of AES-CBC PKCS#7 decrypt operations.
CVE-2024-53845 1 Espressif 1 Esp-idf 2026-04-15 N/A
ESPTouch is a connection protocol for internet of things devices. In the ESPTouchV2 protocol, while there is an option to use a custom AES key, there is no option to set the IV (Initialization Vector) prior to versions 5.3.2, 5.2.4, 5.1.6, and 5.0.8. The IV is set to zero and remains constant throughout the product's lifetime. In AES/CBC mode, if the IV is not properly initialized, the encrypted output becomes deterministic, leading to potential data leakage. To address the aforementioned issues, the application generates a random IV when activating the AES key starting in versions 5.3.2, 5.2.4, 5.1.6, and 5.0.8. This IV is then transmitted along with the provision data to the provision device. The provision device has also been equipped with a parser for the AES IV. The upgrade is applicable for all applications and users of ESPTouch v2 component from ESP-IDF. As it is implemented in the ESP Wi-Fi stack, there is no workaround for the user to fix the application layer without upgrading the underlying firmware.
CVE-2024-47921 2026-04-15 8.4 High
Smadar SPS – CWE-327: Use of a Broken or Risky Cryptographic Algorithm
CVE-2024-36440 1 Swissphone 1 Dical-red 2026-04-15 6.8 Medium
An issue was discovered on Swissphone DiCal-RED 4009 devices. An attacker with access to the file /etc/deviceconfig may recover the administrative device password via password-cracking methods, because unsalted MD5 is used.
CVE-2024-8603 2026-04-15 7.5 High
A “Use of a Broken or Risky Cryptographic Algorithm” vulnerability in the SSL/TLS component used in B&R Automation Runtime versions before 6.1 and B&R mapp View versions before 6.1 may be abused by unauthenticated network-based attackers to masquerade as services on impacted devices.
CVE-2025-6521 2026-04-15 7.6 High
During the initial setup of the device the user connects to an access point broadcast by the Sight Bulb Pro. During the negotiation, AES Encryption keys are passed in cleartext. If captured, an attacker may be able to decrypt communications between the management app and the Sight Bulb Pro which may include sensitive information such as network credentials.
CVE-2025-66017 1 Lfdt-lockness 1 Cggmp21 2026-04-15 N/A
CGGMP24 is a state-of-art ECDSA TSS protocol that supports 1-round signing (requires 3 preprocessing rounds), identifiable abort, and a key refresh protocol. In versions 0.6.3 and prior of cggmp21 and version 0.7.0-alpha.1 of cggmp24, presignatures can be used in the way that significantly reduces security. cggmp24 version 0.7.0-alpha.2 release contains API changes that make it impossible to use presignatures in contexts in which it reduces security.
CVE-2025-3838 2026-04-15 N/A
An Improper Authorization vulnerability was identified in the EOL OVA based connect component which is deployed for installation purposes in the customer internal network. Under certain conditions, this could allow a bad actor to gain unauthorized access to the local db containing weakly hashed credentials of the installer. This EOL component was deprecated in September 2023 with end of support extended till January 2024.